Clarification & prefiltration

GFguard® glass microfiber depth filter cartridges

Glass microfiber depth filtration for clarification and particle reduction of compatible pharmaceutical and bioprocess fluids.

Clarification with depth

GFguard captures suspended particles within the glass microfiber media matrix as well as at its surface. Its depth structure supports clarification and prefiltration duties upstream of membrane filters, chromatography columns and other process equipment.

Select the retention grade and cartridge configuration according to the process fluid, particulate load, flow requirement and downstream protection objective.

Available configurations

Filter mediumGlass microfiber
Retention grades0.6 and 1.2 µm
Nominal diameter2.75 in (7 cm)
Nominal lengths10, 20, 30 and 40 in (25, 50, 75 and 100 cm)
Effective filtration area0.45 m2 per 10 in length
ConnectionsDOE flat-gasket and SOE 222 or 226 O-ring configurations; confirm the selected end-cap format

Materials of construction

Upstream and downstream supportsPolypropylene
Core, outer guard and end capsPolypropylene
Sealing methodThermal bonding
Seal optionsSilicone (S), as listed in the current ordering information; confirm the selected connection configuration

Operating limits

Differential pressure at 0–38 °C80 psi (5.5 bar)
Differential pressure at 66 °C60 psi (4.1 bar)
Differential pressure at 82 °C30 psi (2.1 bar)
Steam-in-placeSaturated steam at 121–135 °C for 30 minutes; confirm the permitted pressure and complete cycle in the current catalogue
Autoclave121–135 °C for 30 minutes at 2 bar, subject to the approved configuration and procedure

A stainless-steel reinforcement ring is required for autoclave or SIP applications. Confirm the compatible end-cap configuration, operating conditions and permitted cycle count before ordering.

Typical application discussions

  • Cell-culture harvest, fermentation-fluid and process-pool clarification
  • Protein-containing process streams and compatible pharmaceutical solutions
  • Prefiltration before membrane filtration and chromatography
  • Particle reduction upstream of ultrafiltration, diafiltration and TFF systems

Selection and qualification

GFguard is a clarification and particle-reduction filter. Assess process-fluid chemistry, exposure time, temperature, sterilization conditions, extractables risk and downstream requirements for the selected configuration. Request current materials, traceability and qualification documentation for the intended application.

Selection support

Discuss your GFguard configuration.

Share your process fluid, particulate load, retention target, flow requirement, operating conditions and downstream protection needs.

Request technical consultation